Guangzhou Jin Lun Electric Equipment Co.,Ltd

19 Years Professional Heat Pump Manufacturer!

 

Home
Products
About Us
Factory Tour
Quality Control
Contact Us
Request A Quote
Home ProductsElectric Air Source Heat Pump

Meeting low temperature working heat pump 380V Low teperature resistance

Meeting low temperature working heat pump 380V Low teperature resistance

  • Meeting low temperature working heat pump 380V Low teperature resistance
  • Meeting low temperature working heat pump 380V Low teperature resistance
  • Meeting low temperature working heat pump 380V Low teperature resistance
  • Meeting low temperature working heat pump 380V Low teperature resistance
  • Meeting low temperature working heat pump 380V Low teperature resistance
Meeting low temperature working heat pump 380V Low teperature resistance
Product Details:
Place of Origin: Guangzhou China
Brand Name: Meeting
Certification: CE ISO CCC UKAS,ROHS
Model Number: MD150D
Payment & Shipping Terms:
Minimum Order Quantity: 5 PCS
Price: Negotiation
Packaging Details: Plywooden case
Delivery Time: 15 days
Payment Terms: T/T, L/C WESTERN UNION
Supply Ability: 800/MONTH
Contact Now
Detailed Product Description
Materail: Galvanized Steel Sheet Contactor: Fuji Brand
Copper Thick: 1 Mm Compressor: With Oil Heater
Working Temperature: -20--45 Degree Insulation: Foam Pack Pipe And Stick On The Machine Innner
Control: Wifi Fucntion Support
High Light:

indoor air source heat pump

,

air temp heat pump

Technology Specification

 

 

Porduct Details

Electric Air heat pump

Certification:CE ISO CCC UKAS,ROHS

Place of Origin:Guangdong, China (Mainland)

Brand Name:Meeting

Model Number:MD150D

Condenser:Double thread copper tube heat exchanger

Evaporator:High efficiency inner thread tube connected with

Throttling Device:Electric expansiona valve

Refrigerant:R417A ,R407A,R410A

Net Weight (kg):320

Compressor:Copeland

Power supply:380V/50HZ

Working air temp range:-25—(45)

 

Feature:

»Indoor unit mainly includes condenser, 4-way valve and expansion valve.

  • Avoid the condenser to be burst in the cold weather, better anti-freezing proctection
  • High efficient, lower heat dissipate

» Outdoor unit comprises evaporator, fan and compressor.

  • Thermostatic heating element for evaporator anti-frosting protection
  • The water connections and the drain pipelines must be protected against frost on site
  • compressor outside ,to reduce noise mostly inside the house.

»Auxiliary electronic heater or solar coiler is on your option

 

» Fashionable design, compact structure, saving the place.

 

»Quiet, lower the noise when the unit is running

 

»Advance control panel. Timer function , automatic defrosting function, optional electrical heating, error messages showed for warning.

 

»It can be work in -25°C low ambient temperature.

 

Hot water output temperature up to 60°C, for domestic hot water or heating.

 

auto-defrosting function included. And cooling is optional

 

Air source heat pump working principle

According to the principle of reverse Carnot cycle, the low-temperature and low-pressure liquid refrigerant exchanges heat with the surrounding air in the evaporator, absorbs the heat Q1 in the air and evaporates into a low-temperature and low-pressure gas state, the temperature of the refrigerant does not change during evaporation, and the low-temperature and low-pressure gas refrigerant After entering the compressor, the compressor is used to do work W. It is compressed into high-temperature and high-pressure gas. Then it enters the condenser. In the condenser, it exchanges heat with indoor water. Part of the heat Q2 of the high-temperature and high-pressure gaseous refrigerant is absorbed by the water. As the temperature rises, the refrigerant radiates heat and condenses and turns into a high-temperature, high-pressure liquid. During the condensation, the temperature of the refrigerant is constant and then enters the expansion valve for throttling. Throttling is a process of rapid cooling, and the refrigerant turns into a low-temperature and low-pressure liquid. This process is just like Contrary to the situation in the compressor, the refrigerant after throttling enters into the evaporator for heat exchange, thereby realizing the entire process of reverse Carnot. This cycle is continuous, and the air source heat pump can work continuously and keep the water temperature constant. Increased
 So Q2=Q1+W in this process

 

 

Packaging Details:

Carton and Wooden Package,

OEM is available

Delivery Time

15 working days after arrival of down payment

 

Use

Business Organizations

Supermarket, shopping malls, shops, department store, star-rated

hotels, restaurants, school, office;

Public Places

subway, airports, stations, bookstores, exhibition halls, stadiums, museums, commercial buildings, hospital;

Entertainments Movie theaters, clubs, bars, cafes, Internet bars, beauty shops

 

 

FAQ

Why us?

1.Timely Delivery, considerate sales after service

2.Many Years quality warranty,OEM service.

3.Top Craftmanship, All products 100% tested

4.Preferential freight by Famous shipping company

5.New Design,Very popular style products recommendation for your local market

 

 

 

Electric Air source heat pump dimension

Meeting low temperature working heat pump 380V Low teperature resistance 0

 

Main part diagarm

Meeting low temperature working heat pump 380V Low teperature resistance 1

Meeting low temperature working heat pump 380V Low teperature resistance 2

Meeting low temperature working heat pump 380V Low teperature resistance 3

Meeting low temperature working heat pump 380V Low teperature resistance 4

Contact Details
Guangzhou Jin Lun Electric Equipment Co.,Ltd

Contact Person: Ms. Alinna

Tel: +86 13922152741

Fax: 86-20

Send your inquiry directly to us (0 / 3000)

Other Products